COVID-19: mitigating transmission via wastewater plumbing systems M Gormley, TJ Aspray, DA Kelly The Lancet Global Health 8 (5), e643, 2020 | 189 | 2020 |
Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig M Gormley, TJ Aspray, DA Kelly, C Rodriguez-Gil PloS one 12 (2), e0171556, 2017 | 77 | 2017 |
An assessment of, and response to, potential cross-contamination routes due to defective appliance water trap seals in building drainage systems M Gormley, JA Swaffield, PA Sleigh, CJ Noakes Building Services Engineering Research and Technology 33 (2), 203-222, 2012 | 40 | 2012 |
Environmental conditions and the prevalence of norovirus in hospital building drainage system wastewater and airflows M Gormley, KE Templeton, DA Kelly, A Hardie Building Services Engineering Research and Technology 35 (3), 244-253, 2014 | 30 | 2014 |
Pressure transient control: Part I—criteria for transient analysis and control JA Swaffield, DP Campbell, M Gormley Building Services Engineering Research and Technology 26 (2), 99-114, 2005 | 22 | 2005 |
Pressure transient control: Part II—Simulation and design of a positive surge protection device for building drainage networks JA Swaffield, DP Campbell, M Gormley Building Services Engineering Research and Technology 26 (3), 195-212, 2005 | 21 | 2005 |
Pressure transient identification of depleted appliance trap seals: a pressure pulse technique DA Kelly, JA Swaffield, LB Jack, DP Campbell, M Gormley Building Services Engineering Research and Technology 29 (2), 165-181, 2008 | 18 | 2008 |
Modelling water reduction effects: Method and implications for horizontal drainage M Gormley, DP Campbell Building Research & Information 34 (2), 131-144, 2006 | 16 | 2006 |
Air pressure transient generation as a result of falling solids in building drainage stacks: definition, mechanisms and modelling M Gormley Building Services Engineering Research and Technology 28 (1), 55-70, 2007 | 15 | 2007 |
The transport of discrete solids in above ground near horizontal drainage pipes: A wave speed dependent model M Gormley, DP Campbell Building and Environment 41 (4), 534-547, 2006 | 15 | 2006 |
Transient free surface flows in building drainage systems J Swaffield Routledge, 2015 | 12 | 2015 |
Pressure transient identification of depleted appliance trap seals: a sinusoidal wave technique DA Kelly, JA Swaffield, LB Jack, DP Campbell, M Gormley Building Services Engineering Research and Technology 29 (3), 219-232, 2008 | 12 | 2008 |
Positive air pressure transient propagation in building drainage and vent systems JA Swaffield, LB Jack, DP Campbell, M Gormley Building Services Engineering Research and Technology 25 (2), 77-88, 2004 | 9 | 2004 |
SARS-CoV-2: The growing case for potential transmission in a building via wastewater plumbing systems M Gormley Annals of Internal Medicine 173 (12), 1020-1021, 2020 | 8 | 2020 |
Bio-aerosol cross-transmission via the building drainage system M Gormley, DA Kelly, TJ Aspray Indoor Air, 132-139, 2014 | 6 | 2014 |
Pro-poor sewerage: solids modelling for design optimisation M Gormley, DD Mara, N Jean, I McDougall Proceedings of the Institution of Civil Engineers-Municipal Engineer 166 (1 …, 2013 | 6 | 2013 |
Modelling solid transport in shallow gradient pipe installations: application to simplified sewerage in an international development context M Gormley, N Jean The Proceedings of the 38th International Symposium CIB W062 on Water Supply …, 2012 | 5 | 2012 |
Transient defect identification in building drainage and vent systems–an application of pressure transient theory and practice. DA Kelly, JA Swaffield, LB Jack, DP Campbell, M Gormley 32nd International Symposium CIB W062 on Water Supply and Drainage for …, 2006 | 5 | 2006 |
Pathogen loading and environmental conditions found in hospital building drainage system wastewater and airflows M Gormley, D Kelly 37th International Symposium CIB W062 on Water Supply and Drainage for …, 2011 | 4 | 2011 |
The effects of surfactant dosed water on solid transport in above ground near horizontal drainage systems M Gormley, DP Campbell Building and environment 42 (2), 707-716, 2007 | 3 | 2007 |