Følg
Ning Jiang
Ning Jiang
West China Hospital, Sichuan University
Verifisert e-postadresse på ieee.org
Tittel
Sitert av
Sitert av
År
The extraction of neural information from the surface EMG for the control of upper-limb prostheses: emerging avenues and challenges
D Farina, N Jiang, H Rehbaum, A Holobar, B Graimann, H Dietl, ...
IEEE Transactions on Neural Systems and Rehabilitation Engineering 22 (4 …, 2014
9592014
Myoelectric Control of Artificial Limbs?? Is There a Need to Change Focus?[In the Spotlight]
N Jiang, S Dosen, KR Muller, D Farina
Signal Processing Magazine, IEEE 29 (5), 152-150, 2012
5442012
Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal
N Jiang, KB Englehart, PA Parker
Biomedical Engineering, IEEE Transactions on 56 (4), 1070-1080, 2009
5042009
Linear and nonlinear regression techniques for simultaneous and proportional myoelectric control
JM Hahne, F Biessmann, N Jiang, H Rehbaum, D Farina, FC Meinecke, ...
IEEE Transactions on Neural Systems and Rehabilitation Engineering 22 (2 …, 2014
4012014
Man/machine interface based on the discharge timings of spinal motor neurons after targeted muscle reinnervation
D Farina, I Vujaklija, M Sartori, T Kapelner, F Negro, N Jiang, ...
Nature biomedical engineering 1 (2), 0025, 2017
3552017
Simultaneous and proportional force estimation for multifunction myoelectric prostheses using mirrored bilateral training
JLG Nielsen, S Holmgaard, N Jiang, KB Englehart, D Farina, PA Parker
Biomedical Engineering, IEEE Transactions on 58 (3), 681-688, 2011
334*2011
Intuitive, Online, Simultaneous and Proportional Myoelectric Control Over Two Degrees of Freedom in Upper Limb Amputees.
N Jiang, H Rehbaum, I Vujaklija, B Graimann, D Farina
IEEE transactions on neural systems and rehabilitation engineering: a …, 2013
3042013
Detection of movement intention from single-trial movement-related cortical potentials
IK Niazi, N Jiang, O Tiberghien, JF Nielsen, K Dremstrup, D Farina
Journal of Neural Engineering 8, 066009, 2011
2812011
Enhanced Low-latency Detection of Motor Intention from EEG for Closed-loop Brain-Computer Interface Applications
R Xu, N Jiang, C Lin, N Mrachacz-Kersting, K Dremstrup, D Farina
IEEE Transactions on Biomedical Engineering, 1-1, 2013
2432013
Efficient neuroplasticity induction in chronic stroke patients by an associative brain-computer interface
N Mrachacz-Kersting, N Jiang, A Stevenson, I Niazi, V Kostic, A Pavlovic, ...
Journal of Neurophysiology 115 (3), 1410-1421, 2016
2422016
Is accurate mapping of EMG signals on kinematics needed for precise online myoelectric control?
N Jiang, I Vujaklija, H Rehbaum, B Graimann, D Farina
IEEE Transactions on Neural Systems and Rehabilitation Engineering 22 (3 …, 2013
2262013
Self-correcting pattern recognition system of surface EMG signals for upper limb prosthesis control
S Amsüss, PM Goebel, N Jiang, B Graimann, L Paredes, D Farina
IEEE Transactions on Biomedical Engineering 61 (4), 1167-1176, 2014
2222014
Extracting Signals Robust to Electrode Number and Shift for Online Simultaneous and Proportional Myoelectric Control by Factorization Algorithms
S Muceli, N Jiang, D Farina
IEEE Transaction on Neural Systems and Rehabilitation Engineering, 1-1, 2013
2072013
EMG-based simultaneous and proportional estimation of wrist/hand dynamics in uni-Lateral trans-radial amputees
N Jiang, JLG Vest-Nielsen, S Muceli, D Farina, A Prasad, M Sahin, ...
Journal of NeuroEngineering and Rehabilitation 9 (1), 42, 2012
2072012
Influence of the training set on the accuracy of surface EMG classification in dynamic contractions for the control of multifunction prostheses
T Lorrain, N Jiang, D Farina
Journal of neuroengineering and rehabilitation 8 (1), 25, 2011
1962011
A closed-loop brain–computer interface triggering an active ankle–foot orthosis for inducing cortical neural plasticity
R Xu, N Jiang, N Mrachacz-Kersting, C Lin, GA Prieto, JC Moreno, ...
IEEE Transactions on Biomedical Engineering 61 (7), 2092-2101, 2014
1842014
User adaptation in long-term, open-loop myoelectric training: implications for EMG pattern recognition in prosthesis control
J He, D Zhang, N Jiang, X Sheng, D Farina, X Zhu
Journal of neural engineering 12 (4), 046005, 2015
1652015
A brain–computer interface for single-trial detection of gait initiation from movement related cortical potentials
N Jiang, L Gizzi, N Mrachacz-Kersting, K Dremstrup, D Farina
Clinical Neurophysiology 126 (1), 154-159, 2015
1582015
Peripheral Electrical Stimulation Triggered by Self-Pace Detection of Motor Intention Enhances Motor Evoked Potentials
IK Niazi, N Mrachacz-Kersting, N Jiang, K Nielsen, D Farina
IEEE Transactions on Neural System and Rehabilitation Engineering, 1-1, 2012
1582012
Effect of arm position on the prediction of kinematics from EMG in amputees
N Jiang, S Muceli, B Graimann, D Farina
Medical and Biological Engineering and Computing 51 (1), 143-151, 2013
1382013
Systemet kan ikke utføre handlingen. Prøv på nytt senere.
Artikler 1–20